Xerox 3050 Service Manual page 26

Table of Contents

Advertisement

STATUS
CODE
CAUSE
CLEARANCE
G O T O RAP
IN
SECTION
2
Recurring out of toner
Replace the toner cartridge.
Toner Cartridge could not find home position, probably
isnot installed correctly.
Failure in the interlock circuit.
Exposure Lamp intensity is detected as too high when
running a copy. This code is present on early versions of
firmware.
Exposure Lamp intensity i s detected as too low when
running a copy.
Cutter could not return to the home position, or did not
move off the home position.
-
-
-
Fuser fault. The fuser is unable t o warm to
110" F
(44' C ) in one minute or less.
Fuser fault. The Fuser Roll temperature is greater than
the maximum allowable temperature for more than
thirty seconds. Maximum temperature is currently
348" F (1 76" C).
A possible cause is that a large amount of narrow copies
were made.
Fuser temperature has exceeded the temperature limit.
This can also occur because the 26
VDC
Bulk Power
Supply has failed.
Check the toner cartridge for correct
installation.
-
- -
-
-
-
- -
-
-
--
Press power off (0) then power on (I).
Press power off (0) then power on (1).
Press power off (0) then power on (1).
Refer to the display on the control panel
and follow the clearance procedure.
Then, press power off (0) then power on (1).
Press power off (0) then power on (1).
Press power off (0) then power on (1). Then
allow the copier time to cool to the
operating temperature
before turning
power back on.
Press power off (0) then power on (1).
J1.O1 Out of Toner
RAP
12.02 Toner
Cartridge Home
Position RAP
LL. 10 Cutter
Interlock Open RAP
C Q 27 Exposure
Control RAP
LL.26 Loss of
Illumination RAP
LL.30 Cutter Fault
RAP
LL.41
Fuser Warm up
Fault
RAP
LL.42 Thermal
Control R A P
LL.43 Fuser
Overtemperature
RAP
31 93
Status Code Entry Chart
1-12
3050

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents