DISABLING THE AUDlTRON
PURPOSE
The purpose i s to provide instructions for
disabling or turning off the Auditron
feature.
INTRODUCTION
There are two methods that can be used to
get out of the auditron mode.
Method
1
The first method is to change the auditron
mode to
0
(zero). Using this method allows
the customer to enable the Auditron
without calling for service.
Method
2
The second method is to disable the
Auditron in diagnostics using the code
[0379]. If
this method is used, the Service
Representative must enable the Auditron
feature.
PROCEDURE
Method
1
1. Have the Auditron Administrator enter
their User Number. The following
message will appear on the display:
SELECT THE SYSTEM LEVEL FUNCTION
2. Enter 99. The following message wiH
appear on the display:
AUDITRON MODE X
The
X
will be
a 3
of 4
depending on
the mode the customer was using.
3.
Enter
0
(zero).
4.
Press th PI. key to exit. The copier is out
of the auditron mode.
Method 2
Enter the diagnostic mode.
Enter the code
(03791
and change the
default value to
0
(zero).
Exit the diagnostic mode.
CHANGING THE AUDITRON
ADMINISTRATOR USER NUMBER
PURPOSE
The purpose
is
to allow changing the
Auditron Administrator user number if the
administrator forgets the number.
INTRODUCTION
Performing this procedure returns the
administrator number back to the default
number of
11 11 1
(five ones).
PROCEDURE
Enter the diagnostic mode.
Enter the code [0371] and change the
default value to 0 (zero).
Exit the diagnostic mode.
Have the individual who is the auditron
administrator
select a
number.
Using the Entering the Auditron Mode
procedure in the User Guide, assist the
individual who will be the Auditron
Administrator to enable the Auditron.
8/94
3030
6-1 3
Enabling the Auditron