Ricoh SH-P1 M020 Field Service Manual page 274

Table of Contents

Advertisement

6. Troubleshooting
1st/2nd Message
Ethernet Board Error
Failed to connect to server for Remote
Diagnostics.
Independent-supply toner
IPDS font error. Turn power switch off
then on. Select Reset IPDS Fonts in
Maintenance.
IPv6 Address already exists Link-local
6
Address(109/209)
Pv6 Address already exists Stateless
Address(109/209)
Pv6 Address already exists Manual
Config. Address(109/209)
Load paper in (tray name) or [Cancel]
to FormFeed.
Option RAM Error
Output tray is full.
Parallel I/F Error
272
Problem/Solution
An error on the Ethernet board is detected.
• Pull out and then re-install the controller board.
The printer cannot communicate with Remote Communication
Gate.
• Check the connection to the Remote Server Gate.
Independent-supply toner is set.
• Use toner recommended for this printer.
IPDS font error has occurred.
• Perform the shutdown procedure, and then turn off the
power of the machine. Turn on the power again, and
then execute [Reset IPDS Fonts].
The same IPv6 address already exists.
• Consult your network administrator.
The same IPv6 address already exists.
• Consult your network administrator.
The same IPv6 address already exists.
• Consult your network administrator.
There is no paper in the specified tray.
• Load the specified paper in the tray; press [JobReset] to
reset the job.
The printer cannot detect an optional SDRAM module. It may
be incorrectly installed.
• Check if it is installed properly.
The output tray is full.
• Remove the paper.
The printer's self diagnostic test failed due to a loopback
error.
• Replace the IEEE 1284 board that caused the error.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sh-p1 m021

Table of Contents