790
D
819
For more details about this SC code error, execute SP5990 to print an SMC report so you can read the
error code. The error code is not displayed on the operation panel.
820
SC824
RTB 24
833
0F30
0F31
0F41
Bank over stacking error
More than 4 PTUs installed.
Fatal kernel error
Due to a control error, a RAM
overflow occurred during system
processing. One of the following
messages was displayed on the
operation panel.
D
0x5032
0x6261
0x554C
Other
Self-Diagnostic Error: CPU
The central processing unit returned
D
an error during the self-diagnostic
test.
Self-diagnostic error 8: Engine I/F
ASIC
ASIC for system control could not be
D
detected. After the PCI configuration,
the device ID for the ASIC could not
be checked.
Excess bank stack
Decrease the number of PTUs to within 4.
• System program defective
• HDD defective
• Controller board defective
• Optional board defective
1. Replace the controller firmware.
2. Replace the Controller board.
3. Replace the optional board or HDD.
P2ERRn n= 1 digit arbitrary number that
shows which error bit is 'ON'.
bad dir
UL
-
• Controller board defective
• Software defective
1. Replace the software.
2. Replace the controller board.
• ASIC (engine board defective)
1. Replace the engine board.