Ricoh SH-P1 M020 Field Service Manual page 216

Table of Contents

Advertisement

5. System Maintenance Reference
7941 003
Log1: Install Date
7941 004
Log1: R: TCounter
5
7941 005
Log2: Serial No.
7941 006
Log2: Refill Flag
7941 007
Log2: Install Date
7941 008
Log2: R: TCounter
214
Displays Year-Month-Date of installation for the AIO
unit in the Log1, this setting updates automatically
through a serial interface with the machine when the
new unit is installed
Default: 8
Displays a logged number in the range "0" to
"99999999" in the Log1. this is the total count at time
of installation
[0 to 99999999 / 0 / 1]
Displays an ASCII string in the Log2, that identifies the
manufacturer
Default: 16
• This data is originally entered as BCD and
changes into a 16-character string in order to
convert it to ASCII.
• However, only 10 bytes can be used to
communicate with the controller, so the 16 bytes
are truncated to 10 bytes.
Displays "RF" when the cartridge requires refilling
Cartridge version number in the Log2
Default: 2
Displays Year-Month-Date of installation for the AIO
unit in the Log2, this setting updates automatically
through a serial interface with the machine when the
new unit is installed
Default: 8
Displays a logged number in the range "0" to
"99999999" in the Log2, this is the total count at time
of installation
[0 to 99999999 / 0 / 1]