5507
Supply Alarm
5507 001 Paper Size
5507 004 MaintenanceKit
5507 009 Cartridge
5507 080 Toner Call Timing
5507 128 Interval: Others
5507 133 Interval: A4
5507 134 Interval: A5
5507 142 Interval: B5
5507 164 Interval: LG
5507 166 Interval: LT
5507 172 Interval: HLT
Paper supply control call setting
Switches the control call on/off for the paper supply.
DFU
[0 to 1 / 0 / 1]
0: No alarm.
1: Sets the alarm to sound for the specified number
transfer sheets for each paper size.
When switched on this function informs the @Remote
supply center that the maintenance kit requires
servicing.
[0 to 1 / 1 / 1]
0: OFF
1: ON
When switched on this function informs the @Remote
supply center that the toner cartridge is almost empty
(near-end).
0: OFF
1: ON
Selects the timing of the toner supply call for @Remote.
0: At Replacement
1: At near end
The "Paper Supply Call Level: nn" SPs specify the
paper control call interval for the referenced paper
sizes. DFU
[00250 to 10000/1000/1]
Engine Service Mode
5
157