5816 002
CE Call
5816 003
Function Flag
5816 007
SSL Disable
5816 008
RCG Connect T/O
5816 009
RCG Write Timeout
5816 010
RCG Read Timeout
5816 011
Port 80
Performs the CE Call at the start or end of the service.
[0 or 1 / 0 / 1 /step]
0: Start of the service
1: End of the service
• This SP is activated only when SP 5816-001 is
set to "2".
Enables or disables the remote service function.
[0 to 1 / 0 / 1]
0: Disabled
1: Enabled
Uses or does not use the RCG certification by SSL
when calling the RCG.
[0 to 1 / 0 / 1]
0: Uses the RCG certification
1: Does no use the RCG certification
Specifies the connect timeout interval when calling the
RCG.
[1 to 90 / 30 / 1 second]
Specifies the write timeout interval when calling the
RCG.
[0 to 100 / 60 / 1 second]
Specifies the read timeout interval when calling the
RCG.
[0 to 100 / 60 / 1 second]
Enables/disables access via port 80 to the SOAP
method.
[0 or 1 / 0 / –]
0: Disabled
1: Enabled
Engine Service Mode
5
169