5846 060
Search option
5846 062
Compl Opt 1
5846 063
Compl Opt 2
This SP uses bit switches to set up the fuzzy search
options for the UCS local address book.
Bit
0
Checks both upper/lower case characters
1
2
Japan Only
3
4
--- Not Used ---
5
--- Not Used ---
6
--- Not Used ---
7
--- Not Used ---
Use this SP to set the conditions for password entry to
access the local address book. Specifically, this SP
limits the password entry to upper case and sets the
length of the password.
[0 to 32 / 0 / 1]
• This SP does not normally require adjustment.
• This SP is enabled only after the system
administrator has set up a group password policy
to control access to the address book.
Use this SP to set the conditions for password entry to
access the local address book. Specifically, this SP
limits the password entry to lower case and defines the
length of the password.
[0 to 32 / 0 / 1step]
• This SP does not normally require adjustment.
• This SP is enabled only after the system
administrator has set up a group password policy
to control access to the address book.