Interface view
Default level
2: System level
Parameters
ipv6-address: Destination IPv6 address of the summary route.
prefix-length: Prefix length of the destination IPv6 address of the summary route, in the range of 0 to
128. It indicates the number of consecutive 1s of the prefix, which defines the network ID.
Description
Use ripng summary-address to configure a summary network to be advertised through the
interface.
Use undo ripng summary-address to remove the summary.
Networks falling into the summary network will not be advertised. The cost of the summary route is
the lowest cost among summarized routes.
Examples
# Assign an IPv6 address with the 64-bit prefix to VLAN-interface 100 and configure a summary with
the 35-bit prefix length.
<Sysname> system-view
[Sysname] interface vlan-interface 100
[Sysname-Vlan-interface100] ipv6 address 2001:200::3EFF:FE11:6770/64
[Sysname-Vlan-interface100] ripng summary-address 2001:200:: 35

timers

Syntax
timers { garbage-collect garbage-collect-value | suppress suppress-value | timeout timeout-value
| update update-value } *
undo timers { garbage-collect | suppress | timeout | update } *
View
RIPng view
Default level
2: System level
Parameters
garbage-collect-value: Interval of the garbage-collect timer in seconds, in the range of 1 to 86400.
suppress-value: Interval of the suppress timer in seconds, in the range of 0 to 86400.
timeout-value: Interval of the timeout timer in seconds, in the range of 1 to 86400.
update-value: Interval of the update timer in seconds, in the range of 1 to 86400.
Description
Use timers to configure RIPng timers.
Use undo timers to restore the default.
By default, the garbage-collect timer is 120 seconds, the suppress timer 120 seconds, the timeout
timer 180 seconds, and the update timer 30 seconds.