IBM SAN512B-6 Installation, Service And User Manual page 164

Ibm storage networking
Table of Contents

Advertisement

Complete the following steps to download the firmware from a USB device to the
replacement blade.
Procedure
140
SAN512B-6 Installation, Service, and User Guide
– firmware (Contains the specific release you are installing)
– firmwareKey
– support
1. Insert the USB device into the active CP blade.
2. Attach a serial cable from the PC to the active CP blade.
3. Log in to the active CP blade as admin if you are not still logged in and enter
usbStorage -e to enable the USB device.
4. Remove the serial cable from the active CP blade and attach it to the standby
CP blade and log in as admin.
5. Run firmwareDownload -s to download the firmware to the standby CP blade.
Enter all requested information. The -s option disables the autoreboot, so you
will have to manually issue a reboot after the download finishes to initiate
firmwarecommit. Use all default values, except use USB [Y] so that USB will
be used for downloading.
6. When the download process finishes, run firmwareDownloadStatus to verify
that the firmware has been updated. The command displays a running
account of the progress of the firmwareDownload command until the command
has completed. The final message is similar to the following and will appear
with a date and time stamp.
Slot 1 (CP0, active): Firmwaredownload command has completed successfully.
7. Ensure that you are still logged in to the standby CP blade (the blade for
which you just changed the firmware level) and type reboot. The reboot of
the standby CP will initiate a firmwarecommit to the secondary partition and
log you out.
Chassis_1: admin> reboot
Broadcast message from root (ttyS0) Fri Jun 17 14:49:45 2016...
The system is going down for reboot NOW !!
INIT: Switching to runlevel: 6
INIT: Sending processes the TERM signal Chassis_1:admin> HAMu Heartbeat down, stop FSS
Unmounting all ##exiting due to signal: 9, pending signals: 0x20000, 0x0
ilesystems.
Please stand by while rebooting the system...
Restarting system.
The system is coming up, please wait...
.
.
.
Fri Jun 17 14:53:13 2016: Doing firmwarecommit now.
Please wait ...
Fri Jun 17 14:55:27 2016: Firmware commit completes successfully.
Validating the filesystem ...
Fri Jun 17 22:36:05 2016: Doing firmwarecommit now.
Please wait ...
Fri Jun 17 22:36:48 2016: Firmware commit completes successfully.
2016/06/17-14:56:50, [SULB-1004], 908, SLOT 2 | CHASSIS, INFO,
2010/06/17-14:56:50, [SULB-1036], 909, SLOT 2 | CHASSIS, INFO,
2010/06/17-14:56:50, [SULB-1002], 910, SLOT 2 | CHASSIS, INFO,
Note: The time stamp on the co-CPU may not be in sync with the main CPU
on the blade. This is not a cause for concern.
8. Log back in to the standby CP blade and enter firmwareDownloadStatus on the
standby CP blade to validate a successful commit. This may take 10 minutes.
9. If you are upgrading through several levels of the Fabric OS, repeat step 5
through step 8 as often as necessary based on the path outlined in the
preceding table. Otherwise, proceed to step 10.
Use firmwareshow to verify the firmware versions.
...Firmwarecommit has completed.
...The new Version: Fabric OS [version]
...Firmwaredownload command completed successfully.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents