Procedure
1. Log in to the standby CP blade as admin. If you need to know the IP address
of the standby blade, run ipaddrshow.
You should remain logged in to the active CP blade in order to monitor it.
2. Run firmwareDownload -s to download the firmware to the replacement
(standby) CP blade. The -s option also disables the autoreboot, so you will have
to manually issue a reboot after the download finishes to initiate
firmwarecommit. Enter all requested information (use default values).
3. When the download process finishes, run firmwareDownloadStatus to verify
that the firmware has been updated. The command displays a running account
of the progress of the firmwareDownload command (if it is still running) until
the command has completed. The final message is similar to the following and
will appear with a date and time stamp.
Slot 1 (CP0, active): Firmwaredownload command has completed successfully.
4. On the standby CP blade (the blade for which you just changed the firmware
level), run reboot. The reboot of the standby CP will initiate a firmwarecommit
to the secondary partition and log you out.
Chassis_1:admin> reboot
Broadcast message from root (ttyS0) Fri Jun 17 14:49:45 2016...
The system is going down for reboot NOW !!
INIT: Switching to runlevel: 6
INIT: Sending processes the TERM signal Chassis_1:admin> HAMu Heartbeat down, stop FSS
Unmounting all f##exiting due to signal: 9, pending signals: 0x20000, 0x0
ilesystems.
Please stand by while rebooting the system...
Restarting system.
The system is coming up, please wait...
.
.
.
Fri Jun 17 14:53:13 2016: Doing firmwarecommit now.
Please wait ...
Fri Jun 17 14:55:27 2016: Firmware commit completes successfully.
Validating the filesystem ...
Fri Jun 17 22:36:05 2016: Doing firmwarecommit now.
Please wait ...
Fri Jun 17 22:36:48 2016: Firmware commit completes successfully.
2016/06/17-14:56:50, [SULB-1004], 908, SLOT 2 | CHASSIS, INFO,
2016/06/17-14:56:50, [SULB-1036], 909, SLOT 2 | CHASSIS, INFO,
2016/06/17-14:56:50, [SULB-1002], 910, SLOT 2 | CHASSIS, INFO,
5. Log back in to the standby CP blade and run firmwareDownloadStatus on the
standby CP blade to validate a successful commit. This may take 10 minutes.
6. If you are upgrading through several levels of the Fabric OS, repeat step 2
through step 5 as often as necessary based on the path outlined in the
preceding table. Otherwise, proceed to step 7.
7. Log out of the standby CP blade and log in to the active CP blade.
8. Proceed to the procedures for verifying operation of the new CP blade.
Downloading firmware from USB device:
About this task
For this task, determine the correct sequence of upgrading firmware versions to
reach your target version.
This section assumes that the new firmware has already been copied onto the USB
device. The folder structure on the USB device must be as follows in order to allow
the device to be enabled:
v IBM>
– config
Use firmwareshow to verify the firmware versions.
...Firmwarecommit has completed.
...The new Version: Fabric OS [version]
...Firmwaredownload command completed successfully.
Chapter 9. Control Processor Blades