B.6 F: Option Settings
No.
(Addr.
Name
Hex)
F1-52
Communication Speed
(03D4)
of Serial Encoder
<2>
Selection
<1> Default setting is determined by parameter A1-02, Control Method Selection.
<2> Available in drive software versions PRG: 1018 and later.
u

F2: Analog Input Card Settings (AI-A3)

No.
(Addr.
Name
Hex)
Analog Input Option
F2-01
Card Operation
(038F)
Selection
F2-02
Analog Input Option
(0368)
Card Gain
F2-03
Analog Input Option
(0369)
Card Bias
u

F3: Digital Input Card Settings (DI-A3)

No.
(Addr.
Name
Hex)
F3-01
Digital Input Option
(0390)
Card Input Selection
Digital Input Option DI-
F3-03
A3 Data Length
(03B9)
Selection
280
LCD Display
Selects the communication speed between the PG-F3 option
and serial encoder.
Ser Enc Comm Spd
0: 1M bps/9600 bps (EnDat 2.2/22 / Hiperface)
0: 1M/9600bps
1: 500k bps/19200 bps (EnDat 2.2/22 / Hiperface)
1: 500k/19200bps
2: 1M bps/38400 bps (EnDat 2.2/22 / Hiperface)
2: 1M/38400bps
3: 1M bps/38400 bps (EnDat 2.2/22 / Hiperface)
3: 1M/38400bps
Note:
LCD Display
0: Option card input terminals V1, V2, and V3 replace drive
AI Function Sel
input terminals A1, A2, and A3.
0: 3ch Individual
1: Input signals to terminals V1, V2, and V3 are added together
1: 3ch Addition
to create the frequency reference.
Sets the gain for the input signal to the analog card.
AI Input Gain
Sets the bias for the input signal to the analog card.
AI Input Bias
LCD Display
0: BCD, 1% units
1: BCD, 0.1% units
2: BCD, 0.01% units
DI Function Sel
3: BCD, 1 Hz units
0: BCD 1%
4: BCD, 0.1 Hz units
1: BCD 0.1%
5: BCD, 0.01 Hz units
2: BCD 0.01%
6: BCD customized setting (5-digit), 0.02 Hz units
3: BCD 1 Hz
7: Binary input
4: BCD 0.1 Hz
The unit and the setting range are determined by F3-03.
5: BCD 0.01 Hz
F3-03 = 0: 255/100% (-255 to +255)
6: BCD(5DG) 0.01 Hz
F3-03 = 1: 40961/100% (-4095 to +4095)
7: Binary
F3-03 = 2: 30000/100% (-33000 to +33000)
When the digital operator units are set to be displayed in Hz or
user-set units (o1-03 = 2 or 3), the units for F3-01 are
determined by parameter o1-03.
Data length Sel
0: 8 bit
0: 8bit
1: 12 bit
1: 12bit
2: 16 bit
2: 16bit
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
Description
Parameter is not available in models 4A0930 and
4A1200.
Description
Description
Values
Page
Default: 0
Range: 0 to 3
Values
Page
Default: 0
Range: 0, 1
Default: 100.0%
Min.: -999.9
Max.: 999.9
Default: 0.0%
Min.: -999.9
Max.: 999.9
Values
Page
Default: 0
Range: 0 to 7
Default: 2
Range: 0 to 2