Setup Group Parameters
Table 4.4
lists parameters available by default in the Setup Group.
If a parameter that needs to be edited is not displayed in the Setup Group, access the parameter through the Programming
Mode.
Parameter
A1-02
Control Method Selection
b1-01
Speed Reference Selection
C1-01
Acceleration ramp 1
C1-02
Deceleration ramp 1
d1-01
Speed Reference 1
d1-02
Speed Reference 2
d1-03
Speed Reference 3
d1-04
Speed Reference 4
d1-26
Leveling Speed
Note: Parameter availability depends on the control mode set in A1-02; some parameters listed above may not be accessible in all
control modes.

◆ Switching Between LOCAL and REMOTE

LOCAL mode is when the drive is set to accept the Up/Down command from the digital operator keypad. REMOTE
mode is when the drive is set to accept the Up/Down command from an external device (via the input terminals or serial
communications, etc.).
Switch the operation between LOCAL and REMOTE using the LO/RE key on the digital operator or via a digital input.
This key is disabled with default settings, but can be enabled by setting parameter o2-01 to 1.
Note: 1. After selecting LOCAL, the LO/RE light will remain lit.
2. The drive will not allow the user to switch between LOCAL and REMOTE during run.
Using the LO/RE Key on the Digital Operator
1.
Turn on the power to the drive. The initial display appears.
Press
. The LO/RE light will light up. The drive is now in LOCAL.
2.
To set the drive for REMOTE operation, press
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Table 4.4 Setup Group Parameters
Name
Step
again.
4.3 The Drive and Programming Modes
Parameter
E1-01
Input Voltage Setting
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
E1-06
Base Frequency
E1-09
Minimum Output Frequency
E1-13
Base Voltage
E2-01
Motor Rated Current
E2-11
Motor Rated Output
L1-01
Motor Overload Protection Selection
Name
Display/Result
- MODE -
DRV
Rdy
Speed Ref(A1/A2)
U1-01= 0.00%
YEA_c
U1-02= 0.00%
RSEQ
U1-03= 0.00A
RREF
ommon
FWD
ALM
DIGITAL OPERATOR JVOP-180
- MODE -
DRV
Rdy
Speed Ref (OPR)
U1-01= 0.00%
U1-02= 0.00%
LSEQ
YEA_
U1-03= 0.00A
LREF
FWD
F1
F2
com-
LO
ESC
RE
mon
RESET
ENTER
RUN
STOP
4
95