Switching Between Local And Remote - YASKAWA A1000 Technical Manual

Hide thumbs Also See for A1000:
Table of Contents

Advertisement

10. Press
to confirm the change.
11. The display automatically returns to the screen shown in Step 4.
12. Press
as many times as necessary to return to the initial display.
n
Setup Group Parameters
Table 4.4
lists the parameters available by default in the Setup Group. Selecting an Application Preset in parameter A1-06 or
from the Application Selection Menu of the Setup Group automatically changes the parameters selected for the Setup Group.
Refer to Application Selection on page 87
Use the Programming Mode to access parameters not displayed in the Setup Group.
Parameter
A1-02
Control Method Selection
b1-01
Frequency Reference Selection 1
b1-02
Run Command Selection 1
b1-03
Stopping Method Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Drive Duty Mode
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
d1-02
Frequency Reference 2
d1-03
Frequency Reference 3
d1-04
Frequency Reference 4
d1-17
Jog Frequency Reference
E1-01
Input Voltage Setting
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
E1-06
Base Frequency
Note: Parameter availability depends on the control mode set in A1-02; some parameters listed above may not be accessible in all control modes.
u

Switching Between LOCAL and REMOTE

LOCAL mode is when the drive is set to accept the Run command from the digital operator RUN key. REMOTE mode is
when the drive is set to accept the Run command from an external device (i.e., input terminals or serial communications).
WARNING! Sudden Movement Hazard. The drive may start unexpectedly if the Run command is already applied when switching from
LOCAL mode to REMOTE mode when b1-07 = 1, resulting in death or serious injury. Be sure all personnel are clear of rotating machinery.
Switch the operation between LOCAL and REMOTE using the LO/RE key on the digital operator or via a digital input.
Note: 1. After selecting LOCAL, the LO/RE light will remain lit.
2. The drive will not allow the user to switch between LOCAL and REMOTE during run.
YASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide
Step
for more information.
Table 4.4 Setup Group Parameters
Name
4.2 The Drive and Programming Modes
Parameter
E1-09
Minimum Output Frequency
E1-13
Base Voltage
E2-01
Motor Rated Current
E2-11
Motor Rated Power
E5-01
Motor Code Selection
E5-02
Motor Rated Power
E5-03
Motor Rated Current
E5-04
Number of Motor Poles
E5-05
Motor Stator Resistance
E5-06
Motor d-Axis Inductance
E5-07
Motor q-Axis Inductance
E5-09
Motor Induction Voltage Constant 1
E5-24
Motor Induction Voltage Constant 2
H4-02
Multi-Function Analog Output Terminal FM Gain
H4-05
Multi-Function Analog Output Terminal AM Gain
L1-01
Motor Overload Protection Function Selection
L3-04
Stall Prevention Selection during Deceleration
Display/Result
Entry Accepted
-PRMSET-
PRG
Decel Time 1
C1-02=
20.0Sec
(0.0~6000.0)
"10.0 sec"
FWD
- MODE -
DRV
Rdy
FREF (OPR)
U1-01= 0.00Hz
U1-02= 0.00Hz
LSEQ
U1-03= 0.00 A
LREF
JOG
FWD
FWD/REV
Name
79
4