Connecting AC Power to a QFX5100 Device

Copyright © 2016, Juniper Networks, Inc.
chassis, which is visible through the mounting bracket.
Secure the grounding lug to the protective earthing terminal with the washers and
3.
screws. See
Figure 54 on page 171

Figure 54: Connecting a Grounding Cable to a 1 U QFX5100 Device

Figure 55: Connecting a Grounding Cable to the 2 U QFX5100-96S Device

Dress the grounding cable and ensure that it does not touch or block access to other
4.
device components and that it does not drape where people could trip over it.
General Safety Guidelines and Warnings on page 239
Grounded Equipment Warning on page 255
Connecting AC Power to a QFX5100 Device on page 171
Connecting DC Power to a QFX5100 Device on page 174
The QFX5100 is shipped from the factory with two power supplies. Each power supply
is a hot-removable and hot-insertable field-replaceable unit (FRU) when the second
power supply is installed and running. You can install replacement power supplies in the
two slots next to the fan modules without powering off the switch or disrupting the
switching function.
Ensure that you have a power cord appropriate for your geographical location available
to connect AC power to the switch.
Before you begin connecting AC power to the switch:
Chapter 12: Connecting the Switch to Power
and
Figure 55 on page
171.