Chapter 24: Safety and Compliance Information
For personal safety, connect the green and yellow wire to safety (earth) ground at both
the device and the supply side of the DC wiring.
The marked input voltage of –48 VDC for a DC-powered device is the nominal voltage
associated with the battery circuit, and any higher voltages are only to be associated
with float voltages for the charging function.
Because the device is a positive ground system, you must connect the positive lead to
the terminal labeled
RTN
, the negative lead to the terminal labeled –48 VDC, and the
earth ground to the device grounding points.
Related
General Safety Guidelines and Warnings on page 239
Documentation
General Electrical Safety Guidelines and Warnings on page 261
DC Power Disconnection Warning on page 268
DC Power Grounding Requirements and Warning on page 269
DC Power Wiring Sequence Warning on page 270
DC Power Wiring Terminations Warning on page 272
Connecting DC Power to an EX2200 Switch
Connecting DC Power to an EX3200 Switch
Connecting DC Power to an EX3400 Switch
Connecting DC Power to an EX4200 Switch
Connecting DC Power to an EX4300 Switch
Connecting DC Power to an EX4500 Switch
Connecting DC Power to an EX4550 Switch
Connecting DC Power to an EX4600 Switch
Connecting DC Power to an EX6200 Switch
Connecting DC Power to an EX8200 Switch
Connecting DC Power to an EX9204 Switch
Connecting DC Power to an EX9208 Switch
Connecting DC Power to an EX9214 Switch
Connecting DC Power to an OCX1100 Switch
Connecting DC Power to an XRE200 External Routing Engine
Connecting DC Power to a QFX3500, QFX3600, or QFX3600-I Device
Connecting DC Power to a QFX5100 Device on page 174
Connecting DC Power to a QFX10002
Connecting DC Power to a QFX10000
Connecting DC Power to a QFX5200
Copyright © 2016, Juniper Networks, Inc.
267

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents