Honda Prelude 1993 Service Manual page 1361

Hide thumbs Also See for Prelude 1993:
Table of Contents

Advertisement

Actuator Test
1. Disconnect the actuator cable from the actuator
rod and disconnect the 4-P connector.
2.
Connect batterv Dower to the D terminal and
ground to the A, B, and C terminals.
3. Connect a vacuum pump to the check valve.
Then apply vacuum to the actuator.
ACTUATOR
View from
terminal side
The actuator rod should pull in completely.
lf the rod pulls in only part-way or not at all, check
for a leaking vacuum line or defective solenoid.
ACTUATOR ROD
o
I -YF
/ \N7
/ A @
/t:#r'.\
VACUUM PUMP GAUGE
a973X-041-XXXXX
4 .
CHECK VALVE
23-283
\
With voltage and vacuum still applied, try to pull
the actuator rod out by hand. You should not be
able to pull out. lf you can. it is defective
Disconnect ground from the C terminal. The ac-
tuator rod should return. lf it does not return but
the vent hose and filter are not plugged, the
solenoid valve assembly is defective.
Repeat steps 2 through 5, and disconnect ground
trom the A terminal. The actuator rod should
return. It it does not retu.n but the vent hose and
tilter ar€ not plugged, the solenoid valve assembly
is defective.
lf you replace the solenoid valve assembly, be sure
to use new O-rings on each solenoid.
o _
8 .

Advertisement