Table 1-5 Manually remove history password records
Operation
Remove
history
password
records
of one or all users
Remove
history
records of one or all
super passwords
Configuring a User Login Password in Interactive Mode
A password can be a combination of characters from the following four types: letters A to Z, a to z,
numbers 0 to 9, and 32 special characters (including the space and ~ ` ! @ # $ % ^ & * ( ) _ + - = { } | [ ]
\ : " ; ' < > , . / ).
The password must conform to the related configuration of password control when you set the local
user password in interactive mode.
Table 1-6 Configure a user login password in interactive mode
Operation
Enter system view
Enter the specified user view
Configure a user login password
in interactive mode
Configuring Login Attempt Times Limitation and Failure Processing Mode
Table 1-7 Configure the login attempts limitation and the failure processing mode
Operation
Enter system view
Enable the login attempts
limitation, configure the maximum
number of attempts and configure
the processing mode used when
the maximum number of attempts
is exceeded.
When the maximum number of attempts is exceeded, the system operates in one of the following
processing mode:
Command
reset
password-control
history-record
[
user-name
user-name ]
reset
password-control
history-record super
[ level level-value ]
Command
system-view
ocal-user user-name
l
password
Command
system-view
password-control
login-attempt
login-times [ exceed
{ lock | unlock |
lock-time time } ]
1-7
Description
Executing this command without the user-name
user-name option removes the history password
records of all users.
Executing this command with the user-name
user-name option removes the history password
records of the specified user.
Executing
this
command
level-value option removes the history records of all
super passwords.
Executing this command with the level level-value
option removes the history records of the super
password for the users at the specified level.
—
—
Optional
Input a password according to the
system prompt and ensure the two
input passwords are consistent.
—
Optional
By default, the maximum number of
attempts is three, and the switch
operates in the lock-time processing
mode when the maximum number of
attempts is exceeded.
without the
level
Description
Description