Log in to the web UI.
1.
Click on the main chassis area to access system management settings.
2.
Select the Management tab.
3.
Click Change password.
4.
Enter your new password, and again to confirm, and click OK.
5.
For security, we suggest that you log out and log in again with your new password.
6.
Monitoring system health
System health can be monitored for high module temperatures and low/high port traffic levels. You may wish to
set up your SNMP trap manager to receive notifications when thresholds levels are exceeded. See the
SNMP notifications" section on page 62
managers (notification hosts)" section on page 64
The default health threshold settings are 60
threshold) of maximum bandwidth capacity for ports. In the majority of cases these default thresholds will provide
adequate warning before packets start to be dropped or the system overheats. A clear notification is generated as
soon as the temperature falls 1
Using the web UI to configure health SNMP notification thresholds
Log in to the web UI.
1.
Click on the module you want to configure, and select the Health tab.
2.
Enter a temperature (in celsius) for the threshold value. The default threshold setting is 60
3.
Click on the port you want to configure, and select the Health tab.
4.
Enter the required traffic percent thresholds. The default thresholds are 75%/50% of maximum bandwidth
5.
capacity.
Click Review/apply, review the changes you have made, and then click Apply to implement the new settings.
6.
ONITORING SYSTEM HEALTH
º
C below the specified threshold, or when traffic falls below the lower threshold.
S
NA™ 10G N
MART
for instructions on enabling notifications, and
for instructions on setting up the SNMP notification manager.
º
C for temperature, and 75% (high threshold) and 50% (low
DRAFT
A
(S
NA-X)
ETWORK
CCESS
MART
"Configuring
"Configuring trap
º
C.
34