4-20 Configuring Your Server
See the table below for the items.
Option
FRB-2 Policy
Boot Monitoring
Thermal Sensor
BMC IRQ
Post Error Pause
AC-LINK
Power On Delay
Time
NOTE:
on AC-LINK feature.
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC-LINK."
System status before AC power off
Operating
Aborting (DC power being off also)
Forced shutdown
* Press the POWER switch continuously for four seconds or longer. This forcibly turns off the
power.
Parameter
Disable FRB2 Timer
[Disable BSP]
Do Not Disable BSP
Retry 3 Times
[Disabled]
5 minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
35 minutes
40 minutes
45 minutes
50 minutes
55 minutes
60 minutes
Disabled
[Enabled]
Disabled
[11]
Disabled
[Enabled]
Stay Off
[Last State]
Power On
[0]-255
See "Power Supply" in Chapter 3 for a detailed explanation
Description
Set the policy to be applied to FRB
level 2 timer.
Indicates whether the boot
monitoring function is enabled or
disabled and the timer value on
booting.
To use this function, install NEC
ESMPRO Agent. Do not use this
function if the system is booted
from the OS without installation of
NEC ESMPRO Agent or CD-ROM.
Set this item to "Disabled" if
ARCServe uses the Disaster
Recovery Option.
Indicates whether the temperature
sensor monitoring function is
enabled or disabled.
Indicates the IRQ of the BMC
interrupt.
Indicates whether POST is
aborted once at the end of POST if
an error occurs during the
execution of POST.
Indicates the AC-LINK function.
Shows the state of the power of
the server.
Specify the time from AC-ON to
DC-ON in AC-LINK status.
Setting of AC-LINK
Stay Off
Last State
Off
On
Off
Off
Off
Off
Your Setting
[
]: Factory-set
Power On
On
On
On