AudioCodes Mediant 800B User Manual page 931

Analog & digital voip media gateway
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

User's Manual
Parameter
Web: Analog Metering
Type
EMS: Metering Type
CLI: metering-type
[MeteringType]
Web: Analog TTX Voltage
Level
EMS: TTX Voltage Level
[AnalogTTXVoltageLevel ]
Charge Codes Table
Web: Charge Codes Table
EMS: Charge Codes
CLI: configure voip > gw
analoggw ChargeCode
[ChargeCode]
Version 6.8
Services for Euro ISDN on page 452).
Determines the metering method for generating pulses (sinusoidal
metering burst frequency) by the FXS port.
[0] 12 KHz = (Default) 12 kHz sinusoidal bursts.
[1] 16 KHz = 16 kHz sinusoidal bursts.
[2] = Polarity Reversal pulses.
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only to FXS interfaces.
Determines the metering signal/pulse voltage level (TTX).
[0] 0V = 0 Vrms sinusoidal bursts.
[1] 0.5V = (Default) 0.5 Vrms sinusoidal bursts.
[2] 1V = 1 Vrms sinusoidal bursts
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only to FXS interfaces.
This table parameter configures metering tones and their time intervals
that the FXS interface generates to the Tel side or the E1 trunk (Euro
ISDN) sends in AOC Facility messages to the PSTN (i.e., PBX).
The format of the ini file table parameter is as follows:
[ChargeCode]
FORMAT ChargeCode_Index = ChargeCode_EndTime1,
ChargeCode_PulseInterval1, ChargeCode_PulsesOnAnswer1,
ChargeCode_EndTime2, ChargeCode_PulseInterval2,
ChargeCode_PulsesOnAnswer2, ChargeCode_EndTime3,
ChargeCode_PulseInterval3, ChargeCode_PulsesOnAnswer3,
ChargeCode_EndTime4, ChargeCode_PulseInterval4,
ChargeCode_PulsesOnAnswer4;
[\ChargeCode]
Where,
EndTime = Period (1 - 4) end time.
PulseInterval = Period (1 - 4) pulse interval.
PulsesOnAnswer = Period (1 - 4) pulses on answer.
For example:
ChargeCode 1 = 7,30,1,14,20,2,20,15,1,0,60,1;
ChargeCode 2 = 5,60,1,14,20,1,0,60,1;
ChargeCode 3 = 0,60,1;
ChargeCode 0 = 6, 3, 1, 12, 2, 1, 18, 5, 2, 0, 2, 1;
Notes:
To associate a configured Charge Code to an outgoing Tel-to-IP call,
use the Outbound IP Routing table.
To configure the Charge Codes table using the Web interface, see
Configuring Charge Codes Table on page 454.
931
56. Configuration Parameters Reference
Description
Mediant 800B Gateway and E-SBC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents