40.1.5.2.1 Configuring GW User Info Table in Web Interface
The following procedure describes how to configure and register users in the GW User Info
table in the Web interface.
Note:
If a User Info file is loaded to the device (as described in ''Configuring GW User
Info Table in Loadable Text File'' on page 612), all previously configured entries are
removed from the table in the Web interface and replaced with the entries from the
loaded User Info file.
To configure the GW User Info table in the Web interface:
1.
Open the GW User Info Table page (Configuration tab > VoIP menu > SIP
Definitions > User Information > GW User Info Table).
2.
Click Add: the following dialog box appears:
3.
Configure the GW User Info table parameters according to the table below.
4.
Click Submit.
5.
To save the changes to flash memory, see ''Saving Configuration'' on page 584.
To register a user, select the user's table entry, and then from the Action button's drop-
down list , choose Register. To un-register a user, select the user, and then from the
Action button's drop-down list , choose Un-Register.
Table 40-2: GW User Info Table Parameter Descriptions
Parameter
Index
[GWUserInfoTable_Index]
PBX Extension
[GWUserInfoTable_PBXExtension]
Global Phone Number
[GWUserInfoTable_GlobalPhoneNu
mber]
Display Name
[GWUserInfoTable_DisplayName]
User's Manual
Figure 40-2: GW User Info Table in Web Interface
Defines an index for the new table record.
Defines the PBX extension number.
The valid value is a string of up to 10 characters.
Defines the "global" phone number for the IP side.
The valid value is a string of up to 20 characters.
Defines the Caller ID of the PBX extension.
The valid value is a string of up to 30 characters.
Mediant 800B Gateway and E-SBC
Description
610