AudioCodes Mediant 800B User Manual page 868

Analog & digital voip media gateway
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

Parameter
Web: Max. 3-Way Conference
EMS: Max In Board Calls
[MaxInBoardConferenceCalls]
Web: Establish Conference Code
EMS: Establish Code
CLI: estb-conf-code
[ConferenceCode]
Web/EMS: Conference ID
CLI: conf-id
[ConferenceID]
User's Manual
[1] Non-AudioCodes Media Server = The Conference-
initiating INVITE (sent by the device) uses only the
ConferenceID as the Request-URI. The conference server
sets the Contact header of the 200 OK response to the actual
unique identifier (Conference URI) to be used by the
participants. This Conference URI is then included (by the
device) in the Refer-To header value in the REFER messages
sent by the device to the remote parties. The remote parties
join the conference by sending INVITE messages to the
conference using this conference URI.
[2] On Board = On-board, three-way conference. The
conference is established on the device without the need of an
external Conference server. You can limit the number of
simultaneous, on-board 3-way conference calls, by using the
MaxInBoardConferenceCalls parameter.
[3] Huawei Media Server = The conference is managed by an
external, third-party Conferencing server. The conference-
initiating INVITE sent by the device, uses only the
ConferenceID as the Request-URI. The Conferencing server
sets the Contact header of the 200 OK response to the actual
unique identifier (Conference URI) to be used by the
participants. The Conference URI is included in the URI of the
REFER with a Replaces header sent by the device to the
Conferencing server. The Conferencing server then sends an
INVITE with a Replaces header to the remote participants.
Notes:
This parameter is applicable only to FXS and BRI interfaces.
Three-way conferencing using an external conference server
is supported only by FXS interfaces.
When using an external conference server (options [0] or [1]),
a conference call with up to six participants can be
established.
Defines the maximum number of simultaneous, on-board three-
way conference calls.
The valid range is 0 to 5. The default is 2.
Notes:
For enabling on-board, three-way conferencing, use the
3WayConferenceMode parameter.
This parameter is applicable only to FXS and BRI interfaces.
Defines the DTMF digit pattern, which upon detection generates
the conference call when three-way conferencing is enabled
(Enable3WayConference is set to 1).
The valid range is a 25-character string. The default is "!" (Hook-
Flash).
Note: If the FlashKeysSequenceStyle parameter is set to 1 or 2,
the setting of the ConferenceCode parameter is overridden.
Defines the Conference Identification string.
The valid value is a string of up to 16 characters. The default is
"conf".
The device uses this identifier in the Conference-initiating INVITE
that is sent to the media server when the
Enable3WayConference parameter is set to 1.