Parameter
EMS: Keep Alive Trap Port
[KeepAliveTrapPort]
CLI: sys-oid
[SNMPSysOid]
[SNMPTrapEnterpriseOid]
[acUserInputAlarmDescription]
[acUserInputAlarmSeverity]
[AlarmHistoryTableMaxSize]
CLI: engine-id
[SNMPEngineIDString]
Web: SNMP Trap Destination Parameters
EMS: Network > SNMP Managers Table
CLI: configure system/snmp trap destination
Note: Up to five SNMP trap managers can be defined.
SNMP Manager
[SNMPManagerIsUsed_x]
Version 6.8
Defines the port of the SNMP network management station to
which the device sends keep-alive traps.
The valid range is 0 to 65534. The default is 162.
To enable NAT keep-alive traps, use the SendKeepAliveTrap
parameter.
Defines the base product system OID.
The default is eSNMP_AC_PRODUCT_BASE_OID_D.
Note: For this parameter to take effect, a device reset is
required.
Defines the Trap Enterprise OID.
The default is eSNMP_AC_ENTERPRISE_OID.
The inner shift of the trap in the AcTrap subtree is added to the
end of the OID in this parameter.
Note: For this parameter to take effect, a device reset is
required.
Defines the description of the input alarm.
Defines the severity of the input alarm.
Defines the maximum number of rows in the Alarm History
table. This parameter can be controlled by the Config Global
Entry Limit MIB (located in the Notification Log MIB).
The valid range is 50 to 1000. The default is 500.
Note: For this parameter to take effect, a device reset is
required.
Defines the SNMP engine ID for SNMPv2/SNMPv3 agents. This
is used for authenticating a user attempting to access the SNMP
agent on the device.
The ID can be a string of up to 36 characters. The default is
00:00:00:00:00:00:00:00:00:00:00:00 (12 Hex octets
characters). The provided key must be set with 12 Hex values
delimited by a colon (":") in the format xx:xx:...:xx. For example,
00:11:22:33:44:55:66:77:88:99:aa:bb
Notes:
For this parameter to take effect, a device reset is required.
Before setting this parameter, all SNMPv3 users must be
deleted; otherwise, the parameter setting is ignored.
If the supplied key does not pass validation of the 12 Hex
values input or it is set with the default value, the engine ID
is generated according to RFC 3411.
Determines the validity of the parameters (IP address and port
number) of the corresponding SNMP Manager used to receive
SNMP traps.
[0] (Check box cleared) = Disabled (default)
[1] (Check box selected) = Enabled