AudioCodes Mediant 800B User Manual page 464

Analog & digital voip media gateway
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

To configure Caller display:
1.
Open the Caller Display Information page (Configuration tab > VoIP menu > GW and
IP to IP > Analog Gateway > Caller Display Information).
2.
Click Add; the following dialog box appears:
3.
Configure caller display per port according to the parameters described in the table
below.
4.
Click Submit, and then save ("burn") your settings to flash memory.
Table 27-3: Caller Display Information Table Parameter Descriptions
Parameter
Index
[CallerDisplayInfo_Index]
Module
[CallerDisplayInfo_Module]
Port
[CallerDisplayInfo_Port]
Port Type
[CallerDisplayInfo_PortType]
Display String
CLI: display-string
[CallerDisplayInfo_DisplayString]
Presentation
CLI: presentation
[CallerDisplayInfo_IsCidRestricted]
User's Manual
(Read-only) Displays the index number of the table record.
(Read-only) Displays the module number on which the port is
located.
(Read-only) Displays the port number.
(Read-only) Displays the port type (FXS or FXO).
Defines the Caller ID string.
The valid value is a string of up to 18 characters.
Note: If you set this parameter to "Private" or "Anonymous",
Caller ID is restricted and the settings of the 'Presentation'
parameter is ignored.
Enables the sending of the caller ID string.
[0] Allowed = The caller ID string is sent when a Tel-to-IP
call is made.
[1] Restricted = The caller ID string is not sent. The Caller
ID is sent to the remote side using only the SIP P-
Asserted-Identity or P-Preferred-Identity headers,
according to the AssertedIdMode parameter.
Note: This parameter is overridden by the 'Presentation'
parameter in the Source Number Manipulation table (see
''Configuring Source/Destination Number Manipulation'' on
page 359).
464
Mediant 800B Gateway and E-SBC
Description
Document #: LTRT-10286

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents