Syslog, Cdr And Debug Parameters - AudioCodes Mediant 800B User Manual

Analog & digital voip media gateway
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

Parameter
Web: SBC Test ID
CLI: sbc-test-id
[SBCtestID]
Test Call Table
Web: Test Call Table
CLI: configure system >
test-call > test-call-table
[Test_Call]

56.3.3 Syslog, CDR and Debug Parameters

The Syslog, CDR and debug parameters are described in the table below.
Parameter
Web: Enable Syslog
EMS: Syslog enable
CLI: syslog
[EnableSyslog]
User's Manual
prefix number.
This feature is applicable to all applications (Gateway and SBC).
Defines the SBC test call prefix (ID) for identifying SBC test calls that
traverse the device to register with an external routing entity such as an
IP PBX or proxy server.
This parameter functions together with the TestCallID parameter, which
defines the prefix of the simulated endpoint. Upon receiving an incoming
call with this prefix, the device removes the prefix, enabling it to forward
the test call to the external entity. Upon receiving the call from the
external entity, the device identifies the call as a test call according to its
prefix, defined by the TestCallID, and then sends the call to the
simulated endpoint.
For example, assume SBCTestID is set to 4 and TestCallID to 2. If a call
is received with called destination 4200, the device removes the prefix 4
and routes the call to the IP PBX. When it receives the call from the IP
PBX, it identifies the call as a test call (i.e., prefix 2) and therefore, sends
it to the simulated endpoint.
The valid value can be any string of up to 15 characters. By default, no
number is defined.
Note: This feature is applicable only to the SBC application.
Defines the local and remote endpoints to be tested.
[ Test_Call ]
FORMAT Test_Call_Index = Test_Call_EndpointURI,
Test_Call_CalledURI, Test_Call_RouteBy, Test_Call_IPGroupID,
Test_Call_DestAddress, Test_Call_DestTransportType, Test_Call_SRD,
Test_Call_ApplicationType, Test_Call_AutoRegister,
Test_Call_UserName, Test_Call_Password, Test_Call_CallParty,
Test_Call_MaxChannels, Test_Call_CallDuration,
Test_Call_CallsPerSecond, Test_Call_TestMode,
Test_Call_TestDuration, Test_Call_Play, Test_Call_ScheduleInterval,
Test_Call_QOEProfile, Test_Call_BWProfile;
[ \Test_Call ]
For a description of this table, see ''Configuring Test Call Endpoints'' on
page 717.
Table 56-21: Syslog, CDR and Debug Parameters
Determines whether the device sends logs and error messages (e.g.,
CDRs) generated by the device to a Syslog server.
[0] Disable (default)
[1] Enable
Notes:
If you enable Syslog, you must enter an IP address of the Syslog
server (using the SyslogServerIP parameter).
Syslog messages may increase the network traffic.
Mediant 800B Gateway and E-SBC
Description
Description
760
Document #: LTRT-10286

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents