4.2.4 Down-line Loading Problems
If
you have a down-line load problem, the user name prompt (Enter user-
name» does not appear on the terminals. Also, no terminals will respond to
keyboard entries.
Two sequences of 900 series message:s on the supervisor port terminal indicate
down-line loading problems. Each is covered in the following sections.
NOTE
Have event logging enabled for events 0.3 and 0.7 on all DECnet
load hosts that may be down-line loading the server. Refer to the
DECnet load host documentation for information about event log-
ging, or see the system manager for the DECnet load host.
4.2.4.1
Down-line Load Starts, Then Fails -
The following sequence of mes-
sage appears on the supervisor port t,erminal at 30 second intervals:
Local -902- Waiting for image load
Local -903- Loading from host load-host-address
Local -912- Load failure, timeout
Problem
The directory with the software image on the load host is not de-
fined. For example, on a load host running V
AXNMS
(V 4.0), the
directory with the MUXserver 100 software image, MOM$LOAD, is
not defined.
. Correction: Have the system manager execute the commands re-
quired to define the directory. For VAXNMS (V 4.0), he should enter
the following statement in the system startup file on the load host,
and then execute the comrnand itself.
$DEFINE/SYSTEM/EXEC/NOLOG MOM$LOAD SYS$SYSROOT:[DECSERVER]
Problem
The MUXserver 100 unit has been incorrectly configured on the load
host, or the server software has not been installed properly.
Correction: Perform the procedures outlined in Section 4.2.4.2,
Downline Load Does Not Start.
CHAPTER
4
MUXserver
100
TROUBLESHOOTING
13