Setting Link Speed And Line Type On The Decmux Ii Unit - Digital Equipment MUXserver 100 Reference Manual

Table of Contents

Advertisement

2.5.2 Setting Link Speed and Line Type on the DECmux II
Unit
Modifying the composite link parameters requires a programmed change only
on the DECmux II unit. Connect a terminal directly to the supervisor port of
the DECmux
II
unit, and execute the following procedure.
On power up the terminal display is
DFMZA - Startup test - F;rmware Vers;on Vx.x-xx
012345678*
Enter < RETURN> and in response to the 'Password>' prompt en-
ter the password. The factory setting is SYSTEM. This gives the
SYS> prompt indicating you are logged into the Supervisor Port.
Enter HELP for a listing of all the commands available or see
Chapter 6, Section 6.3.5 (HELP COlnmand).
The SYSTEM command allows the operator to set the parameter for the A and
B
synchronous composite ports. Table 2-3 lists these parameters, their initial
default values, and allowed options.
Table 2-3 Composite Port Paranleters
Paralneter
Default
Options
Speed
9600 baud
1200,2400,4800,9600,
19200,38400 baud
Modem Control
ENABLE
ENABLE, DISABLE
(NOTE 1)
Line Type
RS-232
RS-232, LONG LINE DRIVE
(NOTE 2)
NOTE
1.
This parameter has no significance in Long Line Drive mode
and is not prompted by the display.
2.
Separate connectors are provided for RS-232 and Long Line
Drive RS-422.
18
CHAPTER 2 SETTING UP THE MUXserver 100 AND ITS TERMINALS