4 Verify the remote log server configuration.
console#show syslog-servers
IP Address/Hostname
------------------------- ------
192.168.2.10
5 Verify the local logging configuration and view the log messages stored in
the buffer (RAM log).
console#show logging
Logging is enabled
Console Logging: level debugging. Console
Messages: 748 Dropped.
Buffer Logging: level notifications. Buffer
Messages: 79 Logged,
File Logging: level critical. File Messages: 973
Dropped.
CLI Command Logging : enabled
Switch Auditing : enabled
Web Session Logging : disabled
SNMP Set Command Logging : disabled
Syslog server
Messages: 0 dropped
412 Messages dropped due to lack of resources.
Buffer Log:
<186> FEB 02 05:53:03 0.0.0.0-1 UNKN[1073741088]:
bootos.c(232) 1 %% Event(0xaaaaaaaa)
<189> FEB 02 05:53:03 0.0.0.0-1 UNKN[1073741088]:
bootos.c(248) 2 %% Starting code... BSP
initialization complete, starting application.
--More-- or (q)uit

Configuring Email Alerting

The commands in this example define the SMTP server to use for sending
email alerts. The mail server does not require authentication and uses the
standard TCP port for SMTP, port 25, which are the default values. Only
Port
514
192.168.2.10 logging: debug.
Monitoring and Logging System Information
Severity
--------------
debugging
Description
----------
Syslog Server