Fip Snooping Configuration Example - Dell PowerConnect 8024 User Configuration Manual

Hide thumbs Also See for PowerConnect 8024:
Table of Contents

Advertisement

Command
show fip-snooping fcf
fcf-mac
[
]
show fip-snooping
enode-mac
enode [
show fip-snooping
vlan_id
statistics {vlan
interface
interface
clear fip-snooping
vlan_id
statistics {vlan
interface
interface

FIP Snooping Configuration Example

In this example, FIP snooping is deployed on a stack of two PowerConnect
switches that are functioning as enterprise data center top of rack (ToR)
switches. Two 10G ports on each stack member (ports 16 and 17 on each
switch) connect to a pair FCoE-facing switches through redundant links.
These ports are designated as default DCBx auto-upstream ports. The 10G
ports that are directly connected to Converged Network Adapters (CNAs) on
individual workstations (ports 1–3 on each switch) are designated as DCBx
default auto-downstream ports.
Purpose
Display information about the interfaces connected to
Fibre Channel forwarder (FCF). Use the optional
parameter to display additional information about the
session with the specified FCF device.
Display information about the interfaces connected to
]
FCoE end nodes (ENodes). Use the optional
parameter to display FIP snooping sessions between the
given FCF-MAC and ENode-MAC.
Display the statistics of the FIP packets snooped for all the
|
FIP snooping-enabled VLANs or for the specified VLAN or
}
interface.
Clear the statistics of the FIP packets snooped for all the
|
FIP snooping-enabled VLANs or for the specified VLAN or
}
interface.
Configuring Data Center Bridging Features
fcf-mac
enode-mac
817

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents