Traffic Monitoring Configuration Examples

This section contains the following examples:

Configuring sFlow

Configuring RMON
Configuring sFlow
This example shows how to configure the switch so that ports 10-15 and port
23 send sFlow datagrams to an sFlow receiver at the IP address 192.168.20.34.
The receiver owner is receiver1, and the timeout is 100000 seconds. A counter
sample is generated on the ports every 60 seconds (polling interval), and 1 out
of every 8192 packets is sampled. Note that sFlow monitoring is not enabled
until a receiver owner string is configured.
To configure the switch:
1 Configure information about the sFlow receiver.
console#configure
console(config)#sflow 1 destination 192.168.30.34
console(config)#sflow 1 destination owner
receiver1 timeout 100000
2 Configure the polling and sampling information for tengigabit Ethernet
ports 10-20.
console(config)#sflow 1 polling te1/0/10-15 60
console(config)#sflow 1 sampling te1/0/10-15 8192
3 Configure the polling and sampling information for tengigabit Ethernet
port 23.
console(config)#interface te1/0/23
console(config-if-Te1/0/23)#sflow 1 polling 60
console(config-if-Te1/0/23)#sflow 1 sampling 8192
4 Verify the configured information.
console#show sflow 1 destination
Receiver Index.................... 1
Owner String...................... receiver1
Time out.......................... 99994
IP Address:....................... 192.168.30.34