Security - NEC SL1100 Features And Specifications Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 2.0
Description
This system supports the following built-in simple security features.
• Warning Message (Watch mode)
Automatically and periodically sends the Watching (VRS) Message from the built-In Speaker on the
Multiline Terminal or external paging adapter during night mode.
Accommodates 3rd Party PIR (Passive Infrared Sensor) or Emergency Button to provide additional
security features such as Auto-Emergency Call with Warning (VRS) Message sending.
• Room Monitoring from Outside
Access Multiline Terminal from outside to monitor the room sound
• Remote Inspection
Automatically ring the terminal with pre-programmed schedule in order to check whether users
answer or not. If not answered, Emergency Call is placed to predefined destination automatically.
Conditions
Warning Message (Watch Mode)
• Watch mode can provide "Watching message" in a preprogrammed interval via internal paging
group terminals and/or external paging group during defined schedule such as night time.
• Watch mode starts and stops automatically according to PRG 20-47-01 setting.
• Watch mode can start and stop manually using Service code (PRG 11-12-63) or function key (
assignment.
• To connect security sensor set PRG 20-46-01 Sensor mode to (1; on) and connect to Door Phone
port instead of Door phone.
• Security sensor can be connected to 3, 4 port of 084M-B1. A maximum of 6 sensors can be
connected.
PRG 82-21 needs to set up according to used sensor.
• Security sensor can start and stop automatically according to PRG 20-48-01 setting.
• Security sensor can start and stop manually using Service code (PRG 11-12-64) or function key
*
(
33 assigned after the timer (PRG 20-55-01) time-outs). (V1.5 or higher)
• When the system receives a sensor detection signal from a Security sensor, either items (1 or 2) or
both items (1 and 2) can be programmed.
1.
A repeated "Warning message" is provided via internal paging group terminals and/or external
paging group.
2.
An emergency call can be placed to a pre-programmed destination using a pre-recorded VRS
message.
After finishing the VRS message, the person at the receiving destination can monitor the
situation using Multiline Terminal defined in PRG 20-46-10. Also, by pressing * key from outside
it is possible to enable a two-way path.
• If all VRS channels are busy, a tone will be provided instead of VRS message, such as Watch,
Warning or for destination message.
• If a VRS message is not recorded, a tone will be provided.
• A VRS message can be provided to extension Speaker only when the extension is idle. But if Watch
or Warning message happened during normal paging is working, normal paging will stop and send
Watch or Warning message.
• Warning messages have a higher priority than Watch messages when both are received at same
time.
• If multiple sensors are detected at the same time, the latest detected sensor's Warning message is
provided.
Features and Specifications Manual
SL1100

Security

S
*