SL1100
• Activating or stopping sensor operations must be set according to sensor specifications.
• If outgoing call restriction is set in a system, the emergency call number must be pre-registered in
restriction allow table, to enable the emergency call to be placed. Even if all trunks are busy, the
emergency call has a higher priority and will placed.
• If not answered at called destination, the system will repeat the emergency call at times specified in
PRG 20-46-08.
• To stop a Warning message or an emergency call, the Service code for cancel "Warning message"
(PRG 11-12-62) must be assigned.
• If the system time is changed while the Watch Mode page is enabled, the page plays immediately
regardless of the assigned time interval.
• If system reset occurs during Watching mode or Security sensor "On" state, these modes
automatically continue after the system reboots.
• If system reset occurs when a "Warning message" is being sent or when placing an emergency call,
S
these states will be cleared. As a result, after the system reboots, the "Warning message" or
emergency call stops.
• If Sensor mode is set (PRG 20-46-01;1) and an SLT is connected instead of a sensor, when the SLT is
off hook the system detects the off hook state in the same way it would detect a sensor.
• The VRS allows you to record up to 100 VRS messages (001-100) when using the compact flash
card. If you are using the built-in VRS, without the compact flash, you can only record one message
(001).
Room Monitoring from outside
• To use the Room Monitoring feature, the caller ID of the outside caller and the monitored extension
number have to set. The monitored extension is set in PRG 13-04-03/04. These programs can be
set by pressing Transfer key in the Speed Dial name setting indication for the outside caller.
1.
Press Transfer key.
2.
Select TRF Mode, 3 (Remote Monitor).
3.
Enter monitored extension number and press Hold key.
• Room monitor functions when the set extension is in an idle state, otherwise a busy tone (ISDN
trunk) or ringback tone (Analogue trunk) is sent to outside caller. If Room Monitor is active, the
terminal will display "Remote Monitored" on the LCD and can not be used.
• By dialing
• If the same outside caller number is set to both Room Monitor and Distinctive ring features, the
feature set in smallest Speed Dial bin number will work.
• If same outside caller number is set for multiple Room monitor extension, the extension set in
smallest Speed Dial bin number is used.
• If multiple outside monitoring telephones are set for one extension, only 1 outside caller can monitor
the room at a time.
If the room is being monitored by another caller, the new calls will receive a Busy Tone on ISDN/SIP
calls. If the caller is on analog trunk, they will hear ring back tone while someone else is monitoring
the extension.
• IP Terminals cannot be used for Room Monitor only, TDM phones can be used for this feature.
Remote Inspection
• When Remote inspection is set to the terminal, "Confirm" and "Ring time" are displayed on the
Multiline Terminal LCD.
• If Remote inspection terminal is busy (receiving another incoming call or on call state), inspection
ring will start after previous call ends.
• When the terminal does not answer inspection ringing during the time assigned in PRG 20-45-03,
emergency calls will be placed to pre-programmed destination with pre-recorded VRS message.
1-652
*
from an outside caller it is possible to use two-way conversation.