ISSUE 2.0
Figure 1-38 Intuition Setup Page 2 - Extension Setting
Table 1-58 Extension (Terminal) Type on page 1-589
Page 2.
Type
Input Range
Digital handsets
0-72
SLT handsets
0-60
DSS Console
0-12
NEC Doorphones 6
When you click "Next" and If you receive the similar message you received in page 1. Like in case of Page
1 please re-enter the number so that it won't exceed the MAX.
Below is example where Terminals exceeds the MAX number.
Features and Specifications Manual
shows type of terminals supported at the Setup
Table 1-58 Extension (Terminal) Type
PRG 10-03-01 (ESI): Terminal Type
• Changed to: MLT
PRG 10-03-02 (ESI): Logical Port
• Changed to: Logical Port Number
MLT is installed per 8 ports base.
So if 9 MLT ports are required 2 MLT related packages need to be instal-
led, port 10-16 is setup as unused MLT handsets.
(PRG 10-03 (ESI)-01 Terminal Type "No Setting")
PRG 10-03-01 (SLI): Logical Port
• Changed to: Logical Port Number
PRG 10-03-05 (SLI): Select Port Type
• Changed to: SLT
SLT is installed per 4 or 8 ports base.
PRG 10-03-01 (ESI): Terminal Type
• Changed to: DSS
PRG 10-03-02 (ESI): Logical Port
• Changed to: Logical Port Number
PRG 10-03-01 (SLI): Logical Port
• Changed to: Logical Port Number
PRG 10-03-05 (SLI): Select Port Type
• Changed to: DoorPhone
Required System Data
SL1100
P