Security Sensor Setup - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

ISSUE 1.0
Level
IN
Description
Use Program 20-46 : Security Sensor Setup to defines the security sensor.
Input Data
Item No.
01
02
03
04
05
06
07
08
09
10
11
Conditions
None
Feature Cross Reference
None
Programming Manual
Downloaded from
www.Manualslib.com
Program 20 : System Option Setup
Security Sensor Number
Item
Sensor Mode
Define door port (408M 6, 7 (SL1000) 084M 3, 4 (SL1100)) to
use as Sensor.
Internal Paging Group for Warning Message
Define Internal paging group number for Warning message
Ring Timer
Define External paging group number for Warning message.
VRS Message for Warning
Define VRS number used for Warning message.
Auto Dial Number Area Setting
Define Speed dial number when sensor detects warning.
VRS Message for Answer
Define VRS message number when emergency call destina-
tion answered.
Auto Dial Wait Timer
Define wait time before making emergency auto dial.
Time of Repeat Auto Dial
Define repeat number for making emergency call.
Auto Dial Calling Time
Define calling continue time when making emergency call.
Monitored Terminal
Define extension number for monitor from outside. IP terminal
cannot set as monitored extension.
Interval of Auto Dial
manuals search engine

20-46 : Security Sensor Setup

1 ~ 8 (SL1000)
1 ~ 6 (SL1100)
Input Data
0 = Off
1 = On
0 ~ 32
0 ~ 8
0 ~ 100
0 ~ 999
0 ~ 100
0 ~ 64800
0 ~ 255
0 ~ 64800
Extension Number (Up
to 4 digits) (SL1000)
Extension Number (Up
to 8 digits) (SL1100)
0 ~ 3600
SL1000/SL1100
Program
20
Default
0
0
0
0
0
0
30
3
30
No setting
0
2-213