NEC SL1100 Features And Specifications Manual page 670

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
Set up Auto Dial Setting for Security Sensor
1.
Press Speaker key + dial 617 at Multiline Terminal.
2.
Dial Security sensor number (1-6), "1".
3.
Dial Speed dial bin number to use, "999".
4.
Dial emergency call destination number "xxx-xxx" and press Hold key.
5.
Dial monitored terminal number, "200".
6.
Dial VRS message number for destination answer, "002".
7.
After beep tone, record the message.
8.
Press Speaker key and finish recording.
To start Security Sensor operation
S
1.
Press Speaker key + dial 719 + 1 at terminal, and sensor is valid after the timer (PRG 20-55-01)
passes. (V1.5 or higher)
- OR -
2.
Press the Function key (
The key lights after the timer (PRG 20-55-01) passes, and sensor is valid.
- OR -
3.
Security Sensor time pattern 1 comes time to start.
To stop Security Sensor operation
1.
Press Speaker key + dial 719 + 0 at terminal.
- OR -
2.
Press the red lit Function key (
- OR -
3.
Security Sensor time pattern 1 comes time to stop.
When detect Security Sensor On
1.
Warning message send to internal page group1 and external page group 1.
2.
Place outgoing call automatically according to speed dial bin 999.
3.
When destination answered send VRS message 2.
4.
After finishing VRS message 2, destination person can monitor through extension 200. By dialing
*
from outside it is possible to make both way talk.
When send Warning message
When send Warning message, but does not place emergency call case:
PRG 20-46-05 is set table number, which has no setting.
When place emergency call
When place emergency call, but does not send Warning message case:
PRG 20-46-02 to PRG 20-46-03 should be set to "0".
Room Monitoring from outside
< Program >
PRG 11-10-45: 610+1/0; Remote Monitor enable/disable.
PRG 13-04-01: Abbreviated Dial Data; set outside telephone number which makes room monitor.
1-658
*
33) at Multiline Terminal and Function key blinks. (V1.5 or higher)
*
33) at Multiline Terminal and the Function key turn off.
ISSUE 2.0
Security

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents