Platform Load Sense System, S-60 Hc - Genie S-60 TraX Service Manual

Hide thumbs Also See for S-60 TraX:
Table of Contents

Advertisement

Section 4 • Repair Procedures
PLATFORM COMPONENTS
11 Test all machine functions from the ground
controls.
Result: All ground control functions should not
operate.
12 Using a suitable lifting device, lift the test weight
off the platform floor.
Result: The platform overload indicator light
should be off at both the ground and platform
controls and the alarm should not sound.
Note: There may be a 2 second delay before the
overload indicator lights and alarm turn off.
13 Test all machine functions from the ground
controls.
Result: All ground control functions should
operate normally.
14 Turn the key switch to platform control.
15 Test all machine functions from the platform
controls.
Result: All platform control functions should
operate normally.
4 - 14
2-4
Platform Load Sense System,
S-60 HC
How to Calibrate the Platform
Load Sense System
Proper calibration of the load sense system is
essential to safe machine operation. Continued use
of an improperly calibrated load sense system
could result in the system failing to sense an
overloaded platform. The stability of the machine is
compromised and it could tip over.
Note: For S-60, S-65, S-60 TRAX and S-65 TRAX
models, refer to Repair Procedure 2-3, Platform
Overload System, S-60, S-65, S-60 TRAX and
S-65 TRAX (if equipped).
Note: Perform this procedure with the boom fully
retracted and in the stowed position and with the
machine on a firm, level surface.
Note: The platform overload system will not allow
partial calibration and must be completed in its
entirety.
1 At the ground controls, turn the key switch to
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
the off position and push in the red Emergency
Stop button to the off position. Pull out the red
Emergency Stop button to the on postion at the
platform controls.
December 2013
Part No. 147753

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-65 traxS-60xS-60xc

Table of Contents