Error Source 41, Load Cell Operational (C175LDS)
Error Type
ID Name
5
Sensor tolerance fault
11 Output short high
12 Value too high
15 Value too low
16 Output short low
17 Not calibrated
18 Just calibrated
Part No. 147753
Load Sense System Fault Codes
Condition
Power relays disengaged.
Power relays disengaged.
Load cell wiring open OR
shorted to voltage.
Power relays disengaged.
Load cell wiring open OR
shorted to voltage.
Platform may be overloaded.
Power relays disengaged.
Load cell wiring open OR
shorted to ground.
Platform may be reverse
loaded.
Power relays disengaged.
Load cell wiring open
OR shorted to ground.
Boom range of
motion is limited.
Used to clear
diagnostic codes.
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Section 5 • Fault Codes
Solution
Repair wiring and/or connections OR
replace platform load cell and calibrate
overload system.
Repair wiring and/or connections
OR replace platform load cell
and calibrate overload system.
Repair wiring and/or connections OR
replace platform load cell OR remove
excess weight from platform.
Repair wiring and/or connections OR
replace platform load cell and
calibrate overload system.
Check for binding of the overload
component linkage and be sure platform
is NOT on the ground OR supported from
underneath.
Repair wiring and/or connections OR
replace platform load cell and calibrate
overload system.
Calibrate the platform load sense
system.
Self-clearing.