Error Source 31, Boom Angle Operational Sensor (C123PBS)
Error Type
ID Name
5
Sensor tolerance fault
11 Output short high
12 Value too high
15 Value too low
16 Output short low
17 Not calibrated
18 Just calibrated
Part No. 147753
Load Sense System Fault Codes
Condition
Power relays disengaged.
Power relays disengaged.
Boom angle sensor
wiring open or shorted
to voltage.
Power relays disengaged.
Boom angle sensor wiring
open or shorted to voltage
OR sensor is out of
operating range.
Power relays disengaged.
Boom angle sensor wiring
open OR shorted to ground
OR sensor is out of
operating range.
Power relays disengaged.
Boom angle sensor wiring
open OR shorted to ground.
Boom range of
motion is limited.
Used to clear
diagnostic codes.
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Section 5 • Fault Codes
Solution
Repair wiring and/or connections OR
replace boom angle sensor and calibrate
overload system.
Repair wiring and/or connections
OR replace boom angle sensor
and calibrate overload system.
Repair wiring and/or connections
OR adjust or replace boom angle sensor
and calibrate overload system.
Repair wiring and/or connections
OR adjust or replace boom angle sensor
and calibrate overload system.
Repair wiring and/or connections
OR replace boom angle sensor
and calibrate overload system.
Calibrate the platform load sense
system.
Self-clearing.