Genie S-60 TraX Service Manual page 184

Hide thumbs Also See for S-60 TraX:
Table of Contents

Advertisement

Section 5 • Fault Codes
Control System Fault Codes
Error Source
ID Name
26 Angle sensor
cross check
31 Primary
Ext. / Ret.
Joystick
32 Primary
Ext. / Ret.
Directional
Valves
33 Primary
Ext. / Ret.
Flow Valve
34 Ext. Ret.
Limit Switch
5 - 4
Error Type
ID Name
19 Out of range
11 Value at 5V
12 Value too high
15 Value too low
16 Value at 0V
17 Not calibrated
21 Fault
12 Value too high
15 Value too low
17 Not calibrated
31 Invalid setup
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Condition
Reduced speed,
required retract into
safe envelope
Function is
inoperative.
Alarm sounds
indicating a fault.
Valve is operating
outside of limits.
Alarm sounds
indicating a fault.
Valve is operating
outside of limits.
Alarm sounds
indicating a fault.
Normal function
except threshold
for one or both
directions is zero.
Initiate 1-second beep
of Alarm Buzzer
-1000lb. Mode:
Required retract into
"FULLY RETRACTED" switches
state before lowering
-500lb. Mode:
Operates normally
December 2013
Solution
Power up controller with
problem corrected
Cycle power off,
then on after
problem has been
corrected.
Calibrate joystick.
Cycle power off,
then on after
problem has been
corrected.
Cycle power off,
then on after
problem has been
corrected.
Calibrate valve
threshold.
Fully retract, then lower
boom
Check and service ext/
ret and fully stowed
Part No. 147753