8 Test all machine functions from the platform
controls.
Result: All platform control functions should not
operate.
9 Turn the key switch to ground control.
10 Test all machine functions from the ground
controls.
Result: All ground control functions should not
operate.
11 Activate the auxiliary power toggle switch.
Note: The engine will turn off when the auxiliary
power is activated.
12 Using auxiliary power, test all machine functions
from the ground controls.
Result: All ground control functions should
operate.
13 Using a suitable lifting device, lift the additional
test weight from the platform.
Result: The platform overload indicator lights
should turn off at both the ground and platform
controls and the alarm should not sound.
Note: There may be an 2 second delay before the
overload indicator lights and alarm turn off.
14 Start the engine and test all machine functions
from the ground controls.
Result: All ground control functions should
operate normally.
15 Turn the key switch to platform control.
Part No. 147753
16 Test all machine functions from the platform
Note: If the platform overload system is not
operating properly, Refer to Repair Procedure 2-3,
How to Calibrate the Platform Overload System (if
equipped), S-60, S-65, S-60 TRAX and S-65 TRAX.
17 Using a suitable lifting device, remove the
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Section 3 • Scheduled Maintenance Procedures
CHECKLIST C PROCEDURES
controls.
Result: All platform control functions should
operate.
remaining test weights from the platform.