12 Activate and release the calibration toggle
switch inside the ground control box 1 time.
Result: The alarm should sound for 1 second
indicating the fourth calibration step was
accepted. The green LED on the operational
controller should be blinking fast and the red
LED should be blinking five times indicating that
step 5 of calibration is next.
13 Fully retract and lower the boom to the stowed
position.
14 Using a suitable lifting device, place an
appropriate test weight equal to
750 lbs / 340.2 kg on to the center of the
platform floor.
Note: If your machine is equipped with any platform
accessories or options, they must be removed from
the platform OR the weights of those options or
accessories must be subtracted from the test
weights to accurately calibrate the platform load
sense system.
15 Activate and release the calibration toggle
switch inside the ground control box 1 time.
Result: The alarm should sound for 1 second
indicating the fifth calibration step was
accepted. The green LED on the operational
controller should be blinking fast and the red
LED should be blinking six times indicating that
step 6 of calibration is next.
16 Using a suitable lifting device, place an
additional test weight equal to 510 lbs / 231.3 kg
on to the center of the platform floor. The total
weight in the platform must equal
1260 lbs / 571.5 kg.
Part No. 147753
17 Activate and release the calibration toggle
18 At the ground controls, push in the red
19 Visually inspect the LEDs on the controllers.
20 At the ground controls, push in the red
21 Using a suitable lifting device, remove the test
22 Pull out the red Emergency Stop button to the
Note: If an LED is blinking on either controller, the
load sense system is not calibrated correctly or a
fault may exist. Refer to Section 5, Fault Codes to
determine the system fault.
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Section 4 • Repair Procedures
PLATFORM COMPONENTS
switch inside the ground control box 1 time.
Result: The alarm should sound for 1 second
indicating the sixth calibration step was
accepted. The engine may turn off and the
alarm may sound indicating an overloaded
platform.
Emergency Stop button to the off position, then
pull out the red Emergency Stop button to the
on position to reset the system.
Result: All LEDs on both controllers should be
off indicating the platform load sense system is
calibrated.
Emergency Stop button to the off position.
weights from the platform.
on position at the ground controls and visually
inspect the LEDs on the operational and safety
controllers.
Result: Both the green and red LEDs on both
controllers should be off indicating the system
is calibrated.