Platform Load Sense System,
S-60 HC
How to Retrieve Platform Load
Sense System Fault Codes
Note: Perform this procedure with the engine off,
the key switch turned to ground controls and the
red Emergency Stop buttons pulled out to the on
position at both the ground and platform controls.
1 Open the ground controls side turntable cover.
2 Locate the operational and safety controllers
near the ground control box.
3 Determine whether a safety or operational fault
exists by visually inspecting which controller
has flashing LEDs.
Note: If the LEDs are flashing on both controllers,
determine the fault code on one controller at a time.
Part No. 147753
Load Sense System Fault Codes
4 Determine the error source: The red LED
5 Determine the error type: The green LED
6 Use the fault code table on the following pages
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
indicates the error source and will flash two
separate codes. The first code will indicate the
first digit of the two digit code, flashing once per
second. It will then pause for 1.5 seconds and
flash the second digit once per 0.5 second.
indicates the error type and will flash two
separate codes. The first code will indicate the
first digit of the two digit code, flashing once per
second. It will then pause for 1.5 seconds and
flash the second digit once per 0.5 second.
to aid in troubleshooting the machine by
pinpointing the area or component affected.
f
e
d
a
green LED (operational control module)
b
red LED (operational control module)
c
operational control module
d
safety control module
e
red LED (safety control module)
f
green LED (safety control module)
Section 5 • Fault Codes
a
b
c
5 - 21