How to Set Up the Oscillate
Directional Valve
Note:Adjustment of the oscillate directional valve
linkage is only necessary when the linkage or valve
has been replaced.
1 Lower the boom to the stowed position.
2 Use a "bubble type" level to be sure the floor is
completely level.
Tip-over hazard. Failure to perform
this procedure on a level floor
could compromise the stability of
the machine resulting in the
machine tipping over.
3 Check the tire pressure in all four tires and add
air if needed to meet specification.
Note: The tires on some machines are foam-filled
and do not need air added to them.
4 Remove the drive chassis cover and the non-
steer axle covers.
5 Place a "bubble type" level across the drive
chassis non-steer end. Check to be sure the
drive chassis is completely level.
6 Remove the heim joint retaining fastener from
the axle.
7 To level the drive chassis, start the engine and
push up or pull down on the threaded rod until
the machine is completely level.
Part No. 147753
8 Verify that the ground and drive chassis are
9 Adjust the heim joint until the hole lines up with
10 Install the heim joint to the axle and tighten the
11 Check to be sure the drive chassis is
12 Measure the distance between the drive chassis
Note: If the distance is not equal and the
adjustment to the linkage was completed with the
ground and drive chassis level, repeat steps 6
through 11 OR consult Genie Industries Service
Department.
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Section 4 • Repair Procedures
completely level.
the retaining fastener hole in the axle.
jam nut.
completely level.
and the non-steer axle on both sides (from the
inside of the drive chassis).