8 Start the engine from the platform controls and
press down the foot switch.
9 Start a timer and simultaneously move the
joystick in either direction full stroke. Note how
long it takes the function to reach maximum
speed. This is the ramp rate.
10 Compare the function ramp rate time with the
table and determine whether the ramp rate time
needs to increase or decrease.
11 Release the foot switch.
12 Activate the joystick and adjust the ramp rate.
Momentarily move the drive enable toggle
switch in the right direction to increase the time
or momentarily move the drive enable toggle
switch in the left direction to decrease the time.
Note: Each time the drive enable toggle switch is
momentarily moved, the time will change in 5%
increments from a default of 100%, with a minimum
of 50% and a maximum of 150%.
13 Repeat steps 9 through 11 for each joystick
controlled machine function.
14 Return the joystick to the neutral position and
wait for approximately 10 seconds to allow the
settings to be saved.
Result: The alarm should sound indicating that
the settings have been saved in memory.
Result: The alarm does not sound. The
minimum or maximum adjustment has been
obtained. No changes can be saved.
Note: Do not operate any machine function during
the 10 second waiting time.
15 Cycle the red Emergency Stop button off, then
back on.
Part No. 147753
Ramp rate (factory settings)
Boom up/down
transition accelerate
transition decelerate
S ramp accelerate
S ramp decelerate
Boom extend/retract
accelerate
decelerate
Turntable rotate
accelerate
decelerate
Drive
accelerate
decelerate to neutral
decelerate, change of direction
decelerate, coasting
decelerate, braking
decelerate, shift from low to high speed
decelerate, shift from high to low speed
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Section 4 • Repair Procedures
PLATFORM CONTROLS
1 second
10 seconds
1 second
0.45 second
2 seconds
0.5 second
2 seconds
0.75 second
2 seconds
0.5 second
0.5 second
0.75 second
1 second
1 second
4 seconds
4 - 7