Perform Engine Maintenance - Deutz Models - Genie S-60 TraX Service Manual

Hide thumbs Also See for S-60 TraX:
Table of Contents

Advertisement

December 2013
6 S-60, S-65, S-60X, S-60XC, S-60 TRAX and
S-65 TRAX: Install the cover at the pivot end of
the boom.
S-60 HC: Install the boom end cover at the pivot
end of the boom while guiding the small cable
from the string potentiometer into the slot of the
cover.
Component damage hazard. The
cable from the string potentiometer
can become damaged if it is
kinked or pinched.
Note: Be sure the cable from the string
potentiometer is correctly routed around the small
pulley before installing the boom end cover.
7 Install the access panels on the sides of the
boom.
8 Start the engine from the ground controls and
fully retract and lower the boom to the stowed
position.
9 Turn the key switch to the platform controls.
10 Extend the boom approximately 2 feet / 0.6 m.
11 Retract the boom. While retracting the boom,
visually inspect the number 2 and number 3
boom tubes.
Result: The number 2 boom tube should not
1
move more than
/
inch / 13 mm before the
2
number 3 boom tube begins to retract.
Note: If the number 2 boom tube moves more than
1
/
inch / 13 mm before the number 3 boom tube
2
begins to retract, the boom extend/retract cables
need to be adjusted. See Repair Procedure 4-5,
How to Adjust the Boom Extend/Retract Cables.
Part No. 147753
B-23
Perform Engine Maintenance -
Deutz Models
Engine specifications require that this procedure be
performed every 400 hours.
Proper engine maintenance, following the engine
manufacturer's maintenance schedule, is essential
to good engine performance and service life. Failure
to perform the maintenance procedures can lead to
poor engine performance and component damage.
Required maintenance procedures and additional
engine information are available in the
Deutz 2011 Series Operation Manual
(Deutz part number 0312-3547).
Deutz 2011 Series Operation Manual
Genie part number
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Section 3 • Scheduled Maintenance Procedures
CHECKLIST B PROCEDURES
139320
3 - 39