Section 3 • Scheduled Maintenance Procedures
CHECKLIST C PROCEDURES
3 Determine the maximum platform capacity.
Refer to the machine serial plate.
4 Using a suitable lifting device, place a test
weight equal to that of the available capacity in
one of the locations shown.
Refer to Illustration 1.
Result: The platform overload indicator lights
should be off at both the ground and platform
controls and the alarm should not sound.
Result: The platform overload indicator lights are
on and the alarm is sounding. Calibrate the
platform overload system. Refer to Repair
Procedure 2-3, How to Calibrate the Platform
Overload System (if equipped), S-60, S-65,
S-60 TRAX and S-65 TRAX.
5 Carefully move the test weight to each
remaining location. Refer to Illustration 1.
Result: The platform overload indicator lights
should be off at both the ground and platform
controls and the alarm should not sound.
Result: The platform overload indicator lights are
on and the alarm is sounding. Calibrate the
platform overload system. Refer to Repair
Procedure 2-3, How to Calibrate the Platform
Overload System (if equipped), S-60, S-65,
S-60 TRAX and S-65 TRAX.
Illustration 1
3 - 44
6 Using a suitable lifting device, place an
Note: There may be a 2 second delay before the
overload indicator lights flash and the alarm
sounds.
7 Carefully move the test weights to each
Note: There may be a 2 second delay before the
overload indicator lights flash and the alarm
sounds.
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
additional 50 lbs / 23 kg of weight onto the
platform.
Result: The alarm should sound.
The platform overload indicator lights should be
flashing at both the ground and platform
controls.
Result: The alarm does not sound and the
platform overload indicator lights are not
flashing. Calibrate the platform overload
system. Refer to Repair Procedure 2-3,
How to Calibrate the Platform Overload System
(if equipped), S-60, S-65, S-60 TRAX and
S-65 TRAX.
remaining location on the platform.
Refer to Illustration 1.
Result: The alarm should sound.
The platform overload indicator lights should be
flashing at both the ground and platform
controls.
Result: The alarm does not sound and the
platform overload indicator lights are not
flashing. Calibrate the platform overload
system. Refer to Repair Procedure 2-3,
How to Calibrate the Platform Overload System
(if equipped), S-60, S-65, S-60 TRAX and
S-65 TRAX.
December 2013