8 Remove the pivot pin retaining fasteners from
both the slave cylinder rod-end pivot pin and the
rotator pivot pin.
9 Use a soft metal drift to remove both pivot pins.
Remove the platform rotator from the machine.
Crushing hazard. The platform
rotator may become unbalanced
and fall if not properly supported.
Note: When installing the platform rotator fasteners,
torque the fasteners to specifications.
10 Lower the jib boom leveling arms.
Crushing hazard. The platform
rotator may become unbalanced
and fall if not properly supported.
Note: When installing the platform rotator fasteners,
torque the fasteners to specifications.
S-65 and S-65 TRAX:
7 Remove the pin retaining fasteners from the jib
boom and jib boom leveling arms to platform
rotator pivot pins. Do not remove the pins.
8 Support the jib boom leveling arms.
9 Use a soft metal drift to drive both pins out, then
remove the platform rotator from the machine.
Bodily injury hazard. The jib boom
leveling arms may fall if not
properly supported.
10 Lower the jib boom leveling arms.
Crushing hazard. The platform
rotator may become unbalanced
and fall if not properly supported.
Note: When installing the platform rotator fasteners,
torque the fasteners to specifications.
Part No. 147753
How to Bleed the Platform
Rotator
Note: This procedure will require two people. Do not
start the engine. Use auxiliary power for this
procedure.
1 Move the function enable toggle switch to either
2 Place a suitable container underneath the
3 Open the top bleed screw on the rotator, but do
4 Move the function enable toggle switch to either
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Section 4 • Repair Procedures
PLATFORM COMPONENTS
side and activate the platform rotate toggle
switch to the right then the left through two
platform rotation cycles, then hold the switch to
the right position until the platform is fully
rotated to the right.
platform rotator.
not remove it.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to
squirt or spray.
side and hold the platform rotate toggle switch
to the left position until the platform is fully
rotated to the left. Continue holding the toggle
switch until air stops coming out of the bleed
screw. Close the bleed screw.
Crushing hazard. Keep clear of the
platform during rotation.
4 - 11