Section 5 • Fault Codes
Control System Fault Codes
Error Source
ID Name
45 Platform Level Switch
46 Primary Extend/Retract 21 Fault
Switch
51 Drive Joystick
53 Drive Flow
Valve (EDC)
5 - 6
Error Type
ID Name
21 Fault
11 Value at 5V
12 Value too high
15 Value too low
16 Value at 0V
17 Not calibrated
12 Value too high
15 Value too low
Frozen at zero
and neutral.
17 Not calibrated
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Condition
Platform level
frozen at neutral
Platform Ext/Ret
frozen at neutral
Limited speed
and direction.
Frozen at zero
and neutral.
Alarm sounds
indicating a fault.
Limited speed
and direction.
problem has been
corrected.
Alarm sounds
indicating a fault.
Normal function
except threshold
for one or both
directions is zero.
December 2013
Solution
Power up controller with
problem corrected
Power up controller with
problem corrected
Cycle power off,
then on after
problem has been
corrected.
Calibrate joystick.
Cycle power off,
then on after
Calibrate valve
threshold.
Part No. 147753