Genie S-60 TraX Service Manual page 185

Hide thumbs Also See for S-60 TraX:
Table of Contents

Advertisement

December 2013
Error Source
ID Name
41 Turntable
Rotate
Joystick
42 Turntable
Rotate
Directional
Valves
43 Turntable
Rotate
Flow Valve
44 Drive Enable
Override
Switch
Part No. 147753
Error Type
ID Name
11 Value at 5V
12 Value too high
15 Value too low
16 Value at 0V
17 Not calibrated
21 Fault
12 Value too high
15 Value too low
17 Not calibrated
21 Fault
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Control System Fault Codes
Condition
Limited speed
and direction
frozen at zero
and neutral.
Alarm sounds
indicating a fault.
Limited direction.
Frozen at zero
and neutral.
Alarm sounds
indicating a fault.
Limited speed
and direction.
Frozen at zero
and neutral.
Alarm sounds
indicating a fault.
Normal function
except threshold
for one or both
directions is zero.
Drive enable
override direction
is frozen at
neutral.
Section 5 • Fault Codes
Solution
Cycle power off,
then on after
problem has been
corrected.
Calibrate joystick.
Cycle power off,
then on after
problem has been
corrected.
Cycle power off,
then on after
problem has been
corrected.
Calibrate valve
threshold.
Cycle power off,
then on after
problem has been
corrected.
5 - 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-65 traxS-60xS-60xc

Table of Contents